Consumers

Consumers

With innovative drug-free pain management medical devices you would get nowhere else, Painezee.com is a one-stop solution for all your pain relief needs - be it support belts for your back pain or electrotherapy devices for home use to relieve your pain.


SHOP NOW >>
Professionals

Professionals

Find the best quality, FDA/CE Certified, specialized professional products for your pain management needs. Our sourcing specialists have left no stone unturned in getting these specialty products from across the globe along with 100% service backup.


SHOP NOW >>
Hospitals / Rehab Centres

Hospitals / Rehab Centres

Get informed about high-end equipments available for pain management and rehabilitation. Connect with our team for special pricing and EMI offers.


SHOP NOW >>
Call : 040-65522402 | Login | Create an account
 
India's First Online Retail Website for Pain Management
 
100% Authentic Products Guarantee
Exclusive National & International Brands
 
Special Discounts with No Compromise on Quality

PainEzee Roscoe Care Tec IV

Brand: Roscoe Medical
Product Code: ZMPCRM076000
Availability: In Stock
Price:
Rs 20,000.00

Qty: - +

The Care Tec IV™ combines the waveforms of Russian, EMS, TENS and IF therapy in a portable unit. The device offers preset modes that can be user defined. Maximum portability and simple operation offering you all the options of a clinical device in a portable package.

Features:

  • Display therapeutic mode
  • Display therapeutic program or Display the cycle time for TENS, lF and RUSS therapeutic mode insetting state.
  • Timer symbol
  • EMS waveform of ramp up and ramp down time
  • Display of waveform pulse width
  • Display the channel 1
  • Display numbers of the output intensity for channel 1
  • (CH1); Display numbers of waveform pulse width or EMS
  • waveform of contraction (working) time insetting state.
  • EMS waveform of contraction (working) time.
  • Display of waveform pulse rate
  • Display numbers of the output intensity for channel 2(CH2);
  • Display numbers of waveform pulse rate or EMS waveform of relaxation time in setting state.
  • Low-battery indicator
  • The device is locked indicator
  • Display numbers of the treatment time or EMS waveform of ramp up and ramp down time
  • EMS waveform of relaxation time
  • Display the channel 2

Specifications:

Technical Information:

1.Channel

Dual, isolated between channels

2. Power supply

9.0V DC -1x6LR61 battery, Adapter output:9.OVdc, 800mA

3. Operating

conditions

5"C to 40"C( 41 "F to 104 T)with a retative humidity of 30o/o-7 5o/o, atmospheric pressure from 700 to 1 060 Hpa

4. Storage

conditions

-10'Cto 50'C (14T to 122T)with a relative humidity of 10%  - 90% atmospheric pressure from 700 to 1060 Hpa

5. Dimensions

4.5x2.55x0.9 inches(L*W*H)

6.Weight

Weight 0.28lbs(With battery)

7.Tolerance

There may be a t5% tolerance of all setting and t10o/o tolerance of output of intensity

8. Timer

 

Adjustable, from 1 to 60 minutes or continuous, Adjustable in l minutes each step. Treatment time countdown

Technical Specification for TENS Mode:

1.Waveform

Mono-phase square Pulse wave

2. Pulse amplitude

Adjustable, 0-100mA peak at 1000 ohm Lobd each channel, 1 mA/SteP.

3. Pulse Width

Adjustable, from 50 to 300us microseconds, 1 0PS/steP

4.Pulse Rate

Adjustable, from 1 to 150H2,1 Hz lstep

5.Burst (p1)

Burst rate:Adjustable, 0.5 - 5Hz; 0.1 Hz lstep Pulse width adjustable' 50-300uS FrequencY fixed = 1 00 Hz.

6.Normal (p2)

The pulse rate and Pulse width are adjustable. lt generates continuous stimulation based on the setting value. Pulse Width

7.Modulation (p3)

The pulse width is automatically varied in a cycle time. The pulse width is decreased from its original setting to 60% in setting cycle time, and then increased from 60% to its original setting in nest setting cycle

time. In this program, pulse rate ('l to 150H2), pulse width (50 to 300us) and cycle time (5 to 30 sec) are fully adjustable

8. Pulse Rate

Modulation (P4)

 

The pulse rate is automatically varied in a cycle time. The pulse rate is decreased from its original setting to 60% in setting cycle time, and then increased from 60% to its original setting in nest setting cycle time. In this program, pulse rate (1 to 150H2), pulse width(50 to 300us) and

cycle time (5 to 30 sec) are fully adjustable'

Technical Specification for EMS Mode:

1. Waveform

Mono-phase square pulse wave

2.Pulse Amplitude

Adjustable, 0-1 00mA peak at 1 000 ohm Load each channel, 1mA/Step.

3.Pulse Width

Adjustable, from 50 to 300pS microseconds, 1 0US/step.

4.Pulse Rate

Adjustable, from 1 to 150 Hz, 1 Hzlstep Contraction time Adjustable, 1 -30 seconds , 1 Sec./ step

5.Relaxation (OFF)

time Adjustable, 0-60 seconds , 1 Sec./ step Ramp time

 

6.Synchronous (P1)

Adjustable, 1 -6 seconds, 1 Sec. / step, The "On" time will increase and decrease

in the setting value. Stimulation of both channels occurs synchronously. The "ON" time including "Contraction", "Ramp Up" and "Ramp Down" time. ON TIME=Contraction + Ramp uP + Ramp down

7.Alternate (p2)

The Stimulation of the CH2 will occur after the lst working of CH1 is completed. In this program, The "ON" time including "Contraction", "Ramp Up" and "Ramp

Down" time. The OFF Time should be equal or more than the ON Time ON TIME=Contraction + Ramp up + Ramp down OFF TIME>ON TIME

8.Delay (p3)

The Stimulation of the CH2 will occur after the 1st working of CH 1 is started+ Delay Time. Delay time is adjustable form 1 to 10 sec. In this program, The "ON" time including "Contraction", "Ramp Up" and "Ramp Down" time.

ON TIME=Contraction + Ramp up + Ramp down.

Technical Specification for IF Mode:

1.Waveform

Bi-phase square pulse

2. Pulse amplitude

Adjustable, 0-70mA peak to peak at 1000 ohm Load each channel, 1mA,/Step.

3.Pulse Rate

Channel 1 - Fundamental frequency: 4000 Hz fixed

Channel 2 - Selectable frequency: 4001 to 4150 Hz

interference frequency: 1 to 150 Hz.

4.Pulse Width

125 micro seconds

5. P1

The pulse rate of the CH'1 is fixed in 4000H2; CH2 pulse rate is increased from 4001 Hz to 4010H2 in a cycle time, and then decreased from 4010H2 to 4001H2 in nest setting cycle time. In this program, CH2 interference frequency is varied from 1Hz to 10H2, cycle time (5 to 30 sec) is fully adjustable. CH 2 pulse rate=4000H2+lnterference frequency

6. P2

The pulse rate of the CH1 is flxed in 4000H2; CH2 pulse rate is increased from 4001H2 to 4150Hz in a cvcle time. And then decreased from 4150H2 to qbOtlz in nest setting cycle time. In this program, CH2 interference frequency is varied from 1Hz to 150H2, cycle time (5 to 30 sec) is fully adjustable. CH 2 pulse rate=4000H2+ Interference frequency

7.p3

The pulse rate of the CH1 is fixed in 4000H2; CH2 pulse rate is increased from 4080H2 to 4'l50Hz in a cycle time, and then decreased from 4150H2 to 4080H2 in nest setting cycle time. In this program, CH2 interference frequency is varied from 80Hz to 150H2, cycle time (5 to 30 sec) is fully adjustable. CH 2 pulse rate=4000H2+lnterference frequency

8.p4

The pulse rate of the CH1 is fixed in 4000H2; CH2 pulse rate is automatically varied in a cycle time. Interference frequency is increased from its original setting to 60% in setting cycle time, and then decreased from 60% to its original setting in nest setting cycle time. In this program, CH2 interference frequency (2 to 150H2) and cycle time (5 to 30 sec) are fully adjustable.CH 2 pulse rate=4000H2+ Interference frequency

Technical Specification for Russian Mode:

1.Waveform

Bl-phase square pulse wave

2. Pulse

amplitude

Adjustable, 0-60mA peak at 1 000 ohm Load each channel, 1.0mA,/step

3. Frequency

 

Carrier Frequency (Fixed):2500H2; Burst frequency: Adjustable, from 20Hz to 80H2, 1.OH2/ step

4. Duty Cycle

50% for P1 andP2 10o/o-50o/o for P2

5. Constant (p1)

Constant stimulation based on setting value. Burst frequency is adjustable from 20Hz to 80 Hz. the duty cycle keep at 50%.

6.Modulation (p2)

Duty cycle is automatically varied in a cycle time. The duty cycle is increase from 10% to 50% in setting cycle time, and then decrease from 5Q% to 10% in next setting time. In this program, burst frequency is adjustable from 20Hzto B0Hz, and the cycle time is adjustable from 5 second to 30 second.

7.Modulation (p3)

Burst frequency is automatically varied in a cycle time. Burst frequency is decreased from the setting value to 20Hzin setting cycle time, and then increased from 20Hz to the setting value in next setting time. In this program, the burst frequency is adjustable from 20Hz to B0Hz, and the cycle time is adjustable from 5 second to 30 second.

Write a review


Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below:



Disclaimer


Product images and information on a page is intended for reference only and cannot be the reason of return as manufacturers make minor changes frequently without any prior notification to us. Product image is representative of the product fofered but may not have the exact attributes. Please read product description for the specific attributes of a product. While we attempt to keep our information accurate, we cannot guarantee it is an accurate representation of the latest formulation/technology of the product. If you have any concerns, please visit the vendor's website. The product information is the view of the product's manufacturer, not the views of us.The products and the claims made about specific products on or through this site have not been evaluated by Painezee.com or the Central Drugs Standard Control Organization, India and are not approved to diagnose, treat, cure or prevent disease. The information provided on this site is for information purpose only and is not intended as a substitute for advice from your physician or other healthcare professional. You should always consult with your physician before using any medical device. Prices and promotions are subject to change without notice.